InverterPLC InverterPLCINDUSTRIAL AUTOMATION SPARE PARTS
Home / Products / Sensor / Keyence NU-EC1 EtherCAT Communication Unit (Genuine, Sourced
Keyence NU-EC1 EtherCAT Communication Unit (Genuine, Sourced to Order) Original Keyence Illustrative image

Photo is an illustration, not a photo of the exact unit you will receive. Need to confirm fitment first? Ask us for photos of the actual unit.

Keyence NU-EC1 EtherCAT Communication Unit (Genuine, Sourced to Order)

Category: Sensor Compatible with: Keyence NU Series Lead time confirmed before payment

Genuine Keyence NU-EC1 EtherCAT communication unit sourced to order - a single communication cable between PC/PLC and the NU series drastically cuts wiring and installation time, with remote management and up to 16 N-bus sensor amplifiers linked. Supplied by I

✓ Fitment: genuine Keyence NU Series — supplied as original stock. We check the nameplate revision against your failed unit before shipment.
2–4 daysdispatch after payment confirmation
SEA · ME · EU · Americasshipping to major markets
12-monthwarranty support

Reply within 24 hours · Data sheet and lead time available on request · MOQ negotiable

Product overview

Genuine Keyence NU-EC1 EtherCAT communication unit sourced to order - a single communication cable between PC/PLC and the NU series drastically cuts wiring and installation time, with remote management and up to 16 N-bus sensor amplifiers linked. Supplied by InverterPLC as an independent seller, not an authorised Keyence distributor; the 12-month warranty is our own seller warranty, not the manufacturer's.

Technical specifications

ModelKeyence NU-EC1
NameCommunication unit that supports EtherCAT
Ethernet
Compliant standardsIEEE802.3u (100BASE-TX)
Transmission rate100 Mbps (100BASE-TX)
Transmission mediaCategory 5e STP cable
Distance between nodes100 m
Communication portsRJ-45 x 2
EtherCAT communication specifications
Supported functionsProcess data object communication (cyclic communication), mailbox communication (message communication), CoE compatible
Sensor connection
Connectable sensorsSensor amplifiers with N-bus support
Connectable units16 units max.
Power feedPower is supplied from this unit via the wiring-saving connector
Allowable passing currentTotal 1,200 mA or less
Indicator lamps
Indicator lampsPower (PWR) green LED; RUN green LED; ERR red LED; sensor communication (N-bus) 2-color green/red LED; link/activity green LED
Ratings
Power supply24 VDC +/-10%, ripple (P-P) 10% or less
Power consumption1,700 mW or less (70 mA or less at 24 V, excluding current supplied to connected amplifiers)
Environmental resistance
Pollution degree2
Operating temperature-20 to +55 degrees C (no freezing)
Relative humidity35 to 85% RH (no condensation)
Vibration resistance10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in X/Y/Z
Material / accessories / weight
Case materialMain unit case / dust cover polycarbonate; power connector polyamide (plug), PBT (socket)
AccessoriesInstruction manual, power supply connector, end unit x 2
WeightApprox. 80 g (including connectors)
Ordering information
ConditionBrand-new genuine Keyence unit, sourced to order; lead time confirmed at quotation (typically 1-3 weeks), inspected before shipment
Warranty12-month seller warranty provided by InverterPLC
Listing noteSupplied as a genuine unit sourced to order by an independent seller. We are not an authorised Keyence distributor; Keyence is a registered trademark of its owner and no OEM warranty is implied.
Image notephotos on this page are actual unit photos (copyright KEYENCE Corporation), shown for product identification only.

Why the NU series cuts wiring and installation time

Open field networking for FS-N series amplifiers (per KEYENCE official materials):

  • Single cable to your PC/PLC - only one communication cable is needed between the PC/PLC and the NU series, drastically reducing wiring and installation time
  • Remote management - read measurement data and rewrite amplifier settings from the PLC side, improving convenience and cutting changeover work
  • EtherCAT ready: cyclic (process data object) and mailbox (message) communication, CoE compatible, dual RJ-45 ports for daisy-chaining at 100 Mbps
  • Powers your amplifiers: the NU-EC1 feeds 24 VDC to the connected N-bus amplifiers through the wiring-saving connector (total 1,200 mA or less) - up to 16 units in one group

Family note: The NU series links N-bus sensor amplifiers (such as the FS-N series) to your PC/PLC with a single communication cable - drastically cutting wiring and installation time, with remote management of amplifier settings for better convenience. This listing is the EtherCAT model NU-EC1; the family also includes NU-EP1 (EtherNet/IP), NU-EC1 (EtherCAT) and NU-DN1 (DeviceNet).

FAQ

Q: Which amplifiers can the NU-EC1 connect to?
A: Sensor amplifiers with N-bus support - in practice the KEYENCE FS-N series digital fiber optic amplifiers. Up to 16 units can be linked in one group (varies with the amplifiers used).

Q: Does the NU-EC1 power the amplifiers?
A: Yes - the unit supplies 24 VDC +/-10% to the connected N-bus amplifiers through the wiring-saving connector (total passing current 1,200 mA or less), so the amplifier group needs no separate power wiring.

Q: What is the lead time for the NU-EC1?
A: This is a genuine unit sourced to order. Lead time is confirmed at quotation, typically 1-3 weeks, and every unit is inspected before shipment.

Typical applications

Model listing

Model suppliedOur part & fitment note
Keyence NU SeriesOriginal stock part — this listing. Same references as the unit you remove; we check the nameplate revision with you before shipment.

Supplied as genuine stock as an independent seller — we are not an authorised distributor and no OEM warranty is implied. Send us a photo of your nameplate and we will confirm the exact revision before shipment.

Warranty & shipping

Why buyers choose us

Send us an inquiry

NAME / EMAIL / MODEL & MESSAGE — REPLY WITHIN 24 HOURS

Replacing another model? The cross-reference table maps OEM part numbers from 10 brands to compatible supply, with availability and a five-point fit-check list.

Prefer to chat? WhatsApp +86 157 0595 3332 · Email sales@inverterplc.com · We reply within 24 hours, quote with lead time and data sheet.

Related Sensor products

Listing note: this is genuine Keyence stock, supplied by InverterPLC as an independent seller. We are not an authorised Keyence distributor, and no manufacturer warranty is implied — the 12-month warranty is ours as seller. All brand names and trademarks remain the property of their respective owners.
WhatsApp: Keyence NU-EC1 EtherCAT Communication Unit (Genuine, Sourced — price & lead time
WhatsApp