Original Keyence
Illustrative image
Photo is an illustration, not a photo of the exact unit you will receive. Need to confirm fitment first? Ask us for photos of the actual unit.
Keyence NU-DN1 DeviceNet Communication Unit (Genuine, Sourced to Order)
Genuine Keyence NU-DN1 DeviceNet communication unit sourced to order - a single communication cable between PC/PLC and the NU series drastically cuts wiring and installation time, with remote management and up to 16 N-bus sensor amplifiers linked. Supplied by
Reply within 24 hours · Data sheet and lead time available on request · MOQ negotiable
Product overview
Genuine Keyence NU-DN1 DeviceNet communication unit sourced to order - a single communication cable between PC/PLC and the NU series drastically cuts wiring and installation time, with remote management and up to 16 N-bus sensor amplifiers linked. Supplied by InverterPLC as an independent seller, not an authorised Keyence distributor; the 12-month warranty is our own seller warranty, not the manufacturer's.
Technical specifications
| Model | Keyence NU-DN1 |
| Connectable units | 16 units max. (varies with the connected sensor amplifiers) |
| Sensor connection | |
| Connectable sensors | Sensor amplifiers with N-bus support |
| Connectable units | 16 units max. |
| Allowable passing current | Total 1,200 mA or less |
| DeviceNet specifications | |
| Supported functions | Remote I/O communication (Poll), Explicit message communication |
| Address setting | 0 to 63 (PGM compatible) |
| Baud rate (automatically switched) | 500 kbps / 250 kbps / 125 kbps |
| Maximum cable length | |
| 500 kbps | 100 m thick cable / 100 m thin cable |
| 250 kbps | 250 m thick cable / 100 m thin cable |
| 125 kbps | 500 m thick cable / 100 m thin cable |
| Ratings | |
| Power supply | 11 to 25 VDC - supplied from the DeviceNet communication power supply; the same power is also fed to all connected amplifiers via this unit |
| Power consumption | 1,480 mW or less (60 mA or less at 24 V, excluding current supplied to the connected sensors) |
| Accessories and weight | |
| Accessories | Instruction manual, DeviceNet communication connector, end unit x 2 |
| Weight | Approx. 65 g (including connectors) |
| Ordering information | |
| Condition | Brand-new genuine Keyence unit, sourced to order; lead time confirmed at quotation (typically 1-3 weeks), inspected before shipment |
| Warranty | 12-month seller warranty provided by InverterPLC |
| Listing note | Supplied as a genuine unit sourced to order by an independent seller. We are not an authorised Keyence distributor; Keyence is a registered trademark of its owner and no OEM warranty is implied. |
| Image note | photos on this page are actual unit photos (copyright KEYENCE Corporation), shown for product identification only. |
Why the NU series cuts wiring and installation time
Open field networking for FS-N series amplifiers (per KEYENCE official materials):
- Single cable to your PC/PLC - only one communication cable is needed between the PC/PLC and the NU series, drastically reducing wiring and installation time
- Remote management - read measurement data and rewrite amplifier settings from the PLC side, improving convenience and cutting changeover work
- DeviceNet ready: I/O polling and explicit messaging, station address 0-63 (PGM compatible), baud rate 125/250/500 kbps auto-switched
- Powers your amplifiers: the same DeviceNet communication power feeds the NU-DN1 and all connected N-bus amplifiers (11-25 VDC, total passing current 1,200 mA or less) - up to 16 units
Family note: The NU series links N-bus sensor amplifiers (such as the FS-N series) to your PC/PLC with a single communication cable - drastically cutting wiring and installation time, with remote management of amplifier settings for better convenience. This listing is the DeviceNet model NU-DN1; the family also includes NU-EP1 (EtherNet/IP), NU-EC1 (EtherCAT) and NU-DN1 (DeviceNet).
FAQ
Q: Which amplifiers can the NU-DN1 connect to?
A: Sensor amplifiers with N-bus support - in practice the KEYENCE FS-N series digital fiber optic amplifiers. Up to 16 units can be linked in one group (varies with the amplifiers used).
Q: Does the NU-DN1 need a separate amplifier power supply?
A: No - the unit and all connected N-bus amplifiers are powered from the DeviceNet communication power supply (11-25 VDC) through the NU-DN1, so the amplifier group needs no extra power wiring.
Q: What is the lead time for the NU-DN1?
A: This is a genuine unit sourced to order. Lead time is confirmed at quotation, typically 1-3 weeks, and every unit is inspected before shipment.
Typical applications
- DeviceNet networking for FS-N series amplifiers, single communication cable between PC/PLC and the NU unit, remote centralized monitoring and setting management
Model listing
| Model supplied | Our part & fitment note |
|---|---|
| Keyence NU Series | Original stock part — this listing. Same references as the unit you remove; we check the nameplate revision with you before shipment. |
Supplied as genuine stock as an independent seller — we are not an authorised distributor and no OEM warranty is implied. Send us a photo of your nameplate and we will confirm the exact revision before shipment.
Warranty & shipping
- Warranty: 12 months against manufacturing defects from delivery date.
- Dispatch: current lead time confirmed by email before payment (typically 1–3 weeks)
- Shipping: worldwide by express courier (DHL / FedEx / UPS) or consolidated sea / air freight.
- Power supply: suitable for 50/60 Hz networks; tropicalized build with conformal coating for humidity and salt fog.
- Terms: MOQ negotiable, data sheet and exact lead time confirmed before payment.
Why buyers choose us
- Original stock part — not an aftermarket substitute
- Nameplate and revision checked against your order before shipment
- Inspected and packed for export; photos of the actual unit on request
- 12-month seller warranty and worldwide shipping
Send us an inquiry
Related Sensor products
Keyence LR-ZH500CP CMOS Laser Sensor (Genuine, Sourced to Order) · Keyence
Keyence LR-X100 CMOS Laser Sensor (Genuine, Sourced to Order) · Keyence
Keyence NU-EP1 EtherNet/IP Communication Unit (Genuine, Sourced to Order) · Keyence
Keyence NU-EC1 EtherCAT Communication Unit (Genuine, Sourced to Order) · Keyence